Описание на DSP MLTPWR/5KVA/ONLINE W/BATT:- INFORM DSP MULTIPOWER DSPMP 1105
-  
- • Product typePower module + batteries• Power5 kVA• InputPhase Configuration 1Ph+N+PE Nominal Voltage 220V/230VMinumum Voltage 160V Maximum Voltage 280V Frequency 45-65 HzPower Factor 0,99• OutputPower Factor 0.8Phase Configuration 1Ph+N+PENominal Voltage 220V / 230V (adjustable)Nominal Current at 220V 23AWave Form Pure Sine WaveTotal Harmonic Distortion at 100% linear load <3%At 100% Non-Linear Load <5%Frequency 50Hz or 60Hz (adjustable)Frequency Tolerance (free running) ±0,2%Frequency Regulation ±1Hz; ±3HzStatik Voltage Regulation (0%-100% load) <1%Crest Factor 3
- 1Transfer Time 0secOverload (100% to 150%) 2.5 minOverload (>150%) Transfer to By PassTotal Efficiency ≥ 92%Greenmode Efficiency ≥ 97%Output Connection TerminalsOutlets (Optional) External Socket Box (2pcs SCHUKO, 4pcs IEC Outlets)• BatteryType Maintenance-Free lead acid batteriesRecharge Time 4-6h up to 90%Voltage 240VDCQuantity per string 20pcsCold start Present• DisplayLED+LCD Display Line Mode, Back up Mode, Eco Mode, Bypass Supply, Battery Low,Battery Bad/Disconnect, Overload, UPS Fault, Interruption during transfer LCD Display Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load%,Battery Voltage, Internal TemperatureSelf Diagnostics Upon Power On, Front Panel Setting and Through Software Control,24h routine Check • ProtectionOverload Protection(w/simulated thermal tripping I-T Curve) Inverter Supply: 105%-150% for 160 secods~2 cycles before switching bypass.Bypass supply: 105%-200% for 500 secods ~ 8 cycles before stopping supply load.Short Circuit Protection Switch Off ImmediatelyOther Protection Overheat, Battery Low • Communication interfaceInterface (Communication Ports) Standard RS232 port and optional RS485, Internal SNMP, Dry Contact CardsMonitoring and Management Software Standard• EnvironmentOperating Temperature 0° C ... + 40° CProposed Temp. To Extend Battery Life 20 - 25° CHumidity up to 90% (non-condensing)Audible Noise at 1m <50 dBProtection Class IP 20• Physical Specifications (Tower Position)Net Weight (power module) 25kg Net Weight (with internal batteries) 55kg Dimensions (mm) (HxWxD)-power module 440x88x680Dimensions (mm) (HxWxD)-w/battery vers 440x176x680 • StandardsStandards EN62040-1-1 (safety); EN62040-2 (EMC); EN62040-3 (performance); EN60950-1
Последно добавени продукти в категорията:
|