INFORM DSP MULTIPOWER DSPMP 1106

- Product type
Power module + batteries

- Power
6 kVA

- Input
Nominal Voltage 220V/230V
Minumum Voltage 160V
Minumum Voltage (at full load) 180V
Maximum Voltage 280V
Frequency 45-65 Hz
Power Factor 0,99%
Input Current Harmonics < 7%

- Output
Nominal Voltage 220V / 230V (adjustable)
Nominal Current 27A
Wave Form Pure Sine Wave
Total Harmonic Distortion < 3%
At 100% Non-Linear Load < 5%
Frequency 50Hz or 60Hz (adjustable)
Frequency Tolerance (synchronized) 0,2%
Static Voltage Regulation(0-100 Load) < 1%
Crest Factor 3
Transfer Time 0sec
Overload (on mains at 110% load) 2 min.
Overload (on mains at 125% load) 5 sec
Overload (on mains at 150% load) Transfer to bypass
Total Efficiency ≥ 90%
Greenmode Efficiency ≥ 97%

- Battery
Type Maintenance Free Dry Type
DC Voltage 240VDC (20 pcs 12V Batteries)
Recharging Time 4-6h up to 90%

- Display
Status on LED+LCD: Line Mode, Back up Mode, Eco Mode, Bypass Supply, Battery Low, Battery Bad/ Disconnect, Overload, UPS Fault, Interruption during transfer
Displayed parameters on LCD: Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load%, Battery Voltage, Internal Temperature
Self Diagnostics: Upon Power On, Front Panel Setting and Through Software Control, 24h routine Check

- Protection
Overload Protection: Bypass transfer time is calculated by simulating a temperature related model of a fuse
Short Circuit Protection: Acts as the ideal current source during the short circuit time
Other Protection: Against excessive (heat, voltage, current) intense battery discharge

- Communication interface
Standard RS232 port and optional RS485, Internal SNMP, Dry Contact Cards

- Environment
Operating Temperature 0° C . + 40° C
Proposed Temp. Extend Battery Life 20 - 25° C
Humidity up to 90% (non-condensing)
Audible Noise at 1m < 50 dB

- Physical Specifications
Net Weight (with internal batteries) 55kg
Dimensions (mm) (HxWxD)-w/battery vers 440*176*680

- Standards
Safety EN50091 - 1
EMC EN50091 - 2
Performance EN62040 - 3, EN50091 - 3
Protection Class IP 20