Nikem Net LTD
МАГАЗИН » UPS » DSP MLTPWR/6KVA/ONLINE W/BATT

Търси в целия магазин:

Интернет Компютри Видео-наблюдение

Вашите продукти:


Пазарска количка - до тук 0.00 лв. / 0.00 € с ДДС
продукти - 0 бр.

DSP MLTPWR/6KVA/ONLINE W/BATT

DSP MLTPWR/6KVA/ONLINE W/BATT
DSP MLTPWR/6KVA/ONLINE W/BATT
(голяма снимка)
2629.00 лв. / 1344.19 с ДДС

бр.

не е налично - не е налично
(продукта отсъства от пазара)

  - в количката 0 бр.
    (от този продукт)

Пазарска количка - до тук 0.00 лв. / 0.00 €
(общо продукти - 0 бр.)




към страницата на DSP MLTPWR/6KVA/ONLINE W/BATT


Описание на DSP MLTPWR/6KVA/ONLINE W/BATT:



INFORM DSP MULTIPOWER DSPMP 1106
 
- Product type
 
Power module + batteries
 
- Power
 
6 kVA
 
- Input
 
Nominal Voltage 220V/230V
 
Minumum Voltage 160V
 
Minumum Voltage (at full load) 180V
 
Maximum Voltage 280V
 
Frequency 45-65 Hz
 
Power Factor 0,99%
 
Input Current Harmonics < 7%
 
- Output
 
Nominal Voltage 220V / 230V (adjustable)
 
Nominal Current 27A
 
Wave Form Pure Sine Wave
 
Total Harmonic Distortion < 3%
 
At 100% Non-Linear Load < 5%
 
Frequency 50Hz or 60Hz (adjustable)
 
Frequency Tolerance (synchronized) 0,2%
 
Static Voltage Regulation(0-100 Load) < 1%
 
Crest Factor 3
 
Transfer Time 0sec
 
Overload (on mains at 110% load) 2 min.
 
Overload (on mains at 125% load) 5 sec
 
Overload (on mains at 150% load) Transfer to bypass
 
Total Efficiency ≥ 90%
 
Greenmode Efficiency ≥ 97%
 
- Battery
 
Type Maintenance Free Dry Type
 
DC Voltage 240VDC (20 pcs 12V Batteries)
 
Recharging Time 4-6h up to 90%
 
- Display
 
Status on LED+LCD
Line Mode, Back up Mode, Eco Mode, Bypass Supply, Battery Low, Battery Bad/ Disconnect, Overload, UPS Fault, Interruption during transfer
Displayed parameters on LCD
Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load%, Battery Voltage, Internal Temperature
Self Diagnostics
Upon Power On, Front Panel Setting and Through Software Control, 24h routine Check
- Protection
 
Overload Protection
Bypass transfer time is calculated by simulating a temperature related model of a fuse
Short Circuit Protection
Acts as the ideal current source during the short circuit time
Other Protection
Against excessive (heat, voltage, current) intense battery discharge
- Communication interface
 
Standard RS232 port and optional RS485, Internal SNMP, Dry Contact Cards
 
- Environment
 
Operating Temperature 0° C . + 40° C
 
Proposed Temp. Extend Battery Life 20 - 25° C
 
Humidity up to 90% (non-condensing)
 
Audible Noise at 1m < 50 dB
 
- Physical Specifications
 
Net Weight (with internal batteries) 55kg
 
Dimensions (mm) (HxWxD)-w/battery vers 440
 
176
 
680
 
- Standards
 
Safety EN50091 - 1
 
EMC EN50091 - 2
 
Performance EN62040 - 3, EN50091 - 3
 
Protection Class IP 20
 










нови продукти

Последно добавени продукти в категорията:



nikem-bg.net 2007г.-2026г.