Sinus Eco Series
 
• Model SES 220
 
• InputPower(kVA) 2Voltage Range110VAC ~ 300VAC ( @ 0% to 25% Load )140VAC ~ 300VAC ( @ 25% to 50% Load )160VAC ~ 300VAC ( @ 50% to 100% Load )Frequency 45Hz ~ 65HzPower Factor >=0.99 ( @full linear load )
 
• OutputOutput Power Factor 0,7Voltage 220V / 230V / 240VACVoltage Regulation <±1% ( till low battery warning signal )Frequency ( Synchronized range ) 3Hz or 1Hz ( selectable )Frequency ( Battery Mode ) 50 / 60Hz±0.1%Harmonic Distortion <3% ( @full linear load ), <6% ( @full non-linear load )Crest Factor 3
1Output Waveform SinusoidalOverload Capacity 100% to 105% : Continous / 106%-120% : 30 seconds / 121%-150% : 10 seconds / >150% : transfer to bypassLine Mode efficiency ±>87%Battery Mode efficiency ±>86%Transfer Time ( AC to DC ) 0msOutlets 3pcs IEC & 2pcs Schuko
• BatteryType Maintenance-free lead acid batteriesRecharge time ( up to 80 % ) 5hoursVoltage 48VDCQuantity 4 pcs 12V 7ahBack Up Time Full Load 3minHalf Load 10minCold Start YES
 
• DisplayLED DisplayNormal Mode, Battery Mode, Bypass Mode, Self-Test, Weak-Bad Batery, Site Wiring Fault, Fault, Overlaod, Load/BatteryLevel
 
• AlarmsBattery Buzzer Sound once every 1.5secodsLow Battery Buzzer Sound once every 0.2secodsOverload Buzzer Sound once every 3secodsNormal alarm Buzzer Sound once every 3secodsFault Countinous Buzzer Sound
 
• ProtectionShort Circuit Bypass Mode
Fuse, Normal Mode: Output Breaker / Electronic Circuit, Battery Mode: Output Breaker / Electronic CircuitBattery Battery Discharge ManagementEPO UPS shuts down immidiatelyOver Temperature Normal Mode: Transfers to Bypass Mode, Battery Mode: UPS shuts down immidiately
• CommunicationInterface(Communication Ports) RS-232Monitoring and Management Software standardOptions Dry Contact Board, USB Board, SNMP Card
 
• EnvironmentTemparature 0°C - 40°CHumidity 0% - 90% ( without condensation )Noise Level(1m Distance) <50dBAProtection Class IP20
 
• Physical SpecificationsNet Weight (kg) 22Dimensions(mm) WxDxH 152x438x322
 
• StandardsStandards EN 62040-1-1 (safety), EN 62040-2(EMC)
 